BSKZS - RP 79-1

Product Identification

Product ID:RP 79-1
MSDS Date:12/17/1990
FSC:6850
NIIN:00F030397
MSDS Number: BSKZS

Responsible Party
CIBA-GEIGY CORP REN PLASTICS DIV
4917 DAWN AVE
EAST LANSING, MI 48823-5605
US

Emergency Phone: 800-888-8372

Info Phone: 517-351-5900

Preparer: M. MUNSELL

Cage: 02684

Contractor
CIBA SPECIALTY CHEMICALS CORPORATION
EAST LANSING, MI 48823-5691 US

Telephone: 517-351-5900

Cage: 02684

Ingredients

METHYL CHLOROFORM (1,1,1-TRICHLOROETHANE) (CHLOROTHENE NU),

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 70%

OSHA PEL 350 PPM

ACGIH TLV: 1900 MG/CUM

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


PROPANE

CAS: 74-98-6

RTECS: TX2275000

OSHA PEL 1000 PPM

ACGIH TLV: SIMPLE ASPHYXIANT


FREON 113, 1,1,2,-TRICHLORO-1,2,2,-TRIFLUOROETHANE,

CAS: 76-13-1

RTECS: KJ4000000

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


ALEX (TETRAFLUOROETHYLENE-ETHYLENE COPOLYMER) *93-3*

CAS: 25038-71-5


<10 GRAMS/LITER

RTECS: 9999999VO

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN & EYE IRRITANT. INHALATION:
ASPHYXIANT, NASAL & RESPIRATORY IRRITANT.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SKIN: DEFATTING. INHALATION: DIZZINESS,
WEAKNESS, FATIGUE, NAUSEA, HEADACHE, UNCONSCIOUSNESS, ASPHYXIATION.
Medical Cond Aggravated by Exposure:SKIN & EYE CONDITIONS

First Aid

First Aid:EYES: FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MINS. SKIN:
WASH THOROUGHLY W/SOAP & WATER, REMOVE CONTAMINATED CLOTHING.
INGESTION: IF CONSCIOUS, DRINK PLENTY OF WATER & DON'T INDUCE
VOMITING. INHALATI ON: REMOVE TO FRESH AIR, GIVE OXYGEN &/OR
ARTIFICIAL RESPIRATION IF NEEDED. OBTAIN MEDICAL ATTENTION IN ALL
CASES. (SEE SUPPLEMENTAL DATA).

Fire Fighting

Flash Point:NON-FLAMMABLE
Extinguishing Media:CO2, DRY CHEMICAL, FOAM, WATER
Fire Fighting Procedures:USE SELF-CONTAINED BREATHING APPARATUS. MAY
BURST IF EXPOSED TO TEMPERATURES >130 F.
Unusual Fire/Explosion Hazard:ALTHOUGH TRICHLOROETHANE WILL NOT BURN,
CERTAIN MIXTURES IN AIR MAY IGNITE MOMENTARILY IN THE PRESENCE OF
SPARK/FLAME. ACID FUMES BE PRESENT DURING FIRE.

Accidental Release

Spill Release Procedures:ABSORB IN ABSORBENT MATERIAL.

Handling

Handling and Storage Precautions:AVOID CONTACT W/SKIN, EYES, CLOTHING.
KEEP CONTAINER CLOSED. USE W/ADEQUATE VENTILATION. DO NOT EXPOSE TO
HEAT OR STORE ABOVE 120F. AVOID SUNLIGHT.
Other Precautions:DON'T SMOKE WHEN USING THIS PRODUCT.

Exposure Controls

Respiratory Protection:USE NIOSH APPROVED ORGANIC VAPOR CARTRIDGE
RESPIRATOR.
Ventilation:GENERAL MECHANICAL & LOCAL EXHAUST IN ACCORDANCE W/ACGIH
RECOMMENDATIONS.
Protective Gloves:IMPERMEABLE
Eye Protection:SPLASH-PROOF CHEMICAL GOGGLES
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING. LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
NOTE TO PHYSICIAN: A TEMPORARY CONDITION KNOWN AS POLYMER FUME FEVER
(CHEST DISCOMFORT & COUGHING) MAY RESULT FROM A COMBINATION OF
SMOKE & INHALED FLOUROPOLYMER.

Chemical Properties

Boiling Pt:B.P. Text:117 F
Vapor Pres:70 PSI
Vapor Density:>1
Evaporation Rate & Reference:(BU AC=1): 1.7
Solubility in Water:INSOLUBLE
Appearance and Odor:WHITE LIQUID, SOLVENT ODOR
Percent Volatiles by Volume:>99

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:DIRECT SUNLIGHT, TEMPERATURES >120F (49C),
& OTHER IGNITION SOURCES
Hazardous Decomposition Products:ACID FUMES, HYDROCARBONS

Disposal

Waste Disposal Methods:CONSULT QUALIFIED PERSONNEL FOR METHOD THAT
COMPLIES W/LOCAL, STATE, & FEDERAL REGULATIONS. UN 1956,
NON-FLAMMABLE GAS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.